Sign in / Sign Up About Us Contact Us info@dentalplaza.co.uk

Medical Equipment 8.4 inch Patient monitor SPO2/ECG/NIBP/RESPRIATION/CMRR CMS6000A

  • (out of stock)

    Medical Equipment 8.4 inch Patient monitor SPO2/ECG/NIBP/RESPRIATION/CMRR CMS6000A

  • PRICE: £596.99 WAS: £835.78
  • Feature
    1. 8.4” color TFT display
    2. Unique digital SPO technology with excellent measurement and interference-free
    3. Audible and visual alarms with adjustable alarm range
    4. Anti electrosurgical interference and defibrillation
    5. Can be connected with LAN to work with central monitoring system
  • Promotion

    Buy 2-4 For £567.00 Each And Save Extra 5%

    Buy 5 For £537.00 Each And Save Extra 10%

  • - +
  • Please choose a specification

  • OUT OF STOCK

  • Free Shipping. Some Items Stock in UK. 3-5 Days to Receive

    12 Months Warranty

    Paypal Supports: payment

Item has been added to your basket.

View basket Keep Shopping X

Medical Equipment 8.4 inch Patient monitor SPO2/ECG/NIBP/RESPRIATION/CMRR

 

Features

1. 8.4” color TFT display
2. Unique digital SPO technology with excellent measurement and interference-free
3. Audible and visual alarms with adjustable alarm range
4. Anti electrosurgical interference and defibrillation
5. Can be connected with LAN to work with central monitoring system
6. Powerful data management and storage capacity
7. Suitable for adult, pediatric and neonatal patient
8. Standard configuration: ECG, NIBP, SPO2, PR, Built-in rechargeable battery
9. Optional:RESP, TEMP, 2-TEMP, 2-IBP, ETCO2, Thermal printer

 

Technical Specifications

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection: I, II, III, avR, avL, avF, V
Waveform: 2 ch
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
HR and Alarm Range:
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ±1% or ±1bpm, which great
Resolution: 1 bpm
Sensitivity: >200uV P-P
Differential Input Impedance: >5MΩ


CMRR
Monitor: >105dB
Operation: >105dB
Diagnosis: >85dB
Electrode offset potential: 300mV
Leakage Current: <10uA
Baseline Recovery: <3s after Defi.
ECG Signal Range: 8mV(Vp-p)
Calibration Signal: 1mV (Vp-p), 5% Accuracy
ST Segment measure and alarm: -2.0 ~ +2.0 mV


NIBP
Method: Oscillometry
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90Min
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm Range

 

SPO2
Measuring Range: 0 ~ 100%
Alarm Range: 0 ~ 100%
Resolution: 1%
Accuracy:
70% ~ 100%: 2 %
0% ~ 69%: unspecified
Actualization interval: About 1Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 0~254bpm
Resolution: 1bpm
Accuracy: 2bpm
Alarm Delay: 10 Sec.

 

RESPIRATION
Method: RA-LL impedance 
Pediatric/Neonatal: 6-150rpm 
Alarm range: Adult: 6-120rpm 
Pediatric/Neonatal: 6-150rpm 
Apnea alarm: YES

 

Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN: 20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100 mmHg
MEAN: 20 ~ 110 mmHg
Resolution: 1mmH
Over-pressure protection: YES